- Overall Dimensions 27.75" H x 20.75" W x 9" D (70.5 x 52.7 x 22.9 cm)
- Inlet Connection: 3/4" FNPT
- Outlet Connection: 3/4" FNPT
- Service Flow Rate: Maximum 5 gpm (19 Lpm)
- Rated Capacity: 20,000 gallons (75,700L)
- Pressure Requirements 20 - 100 psi (1.4 – 6.9 bar), non-shock
- CC1E extended service cartridge contains radial flow granular activated carbon (GAC)
- High pressure housing includes head with pressure relief valve, mounting bracket and bowl
- Integral inlet and outlet pressure gauge monitors operation
- Change cartridges on a regular six (6) month preventative maintenance program
- Change cartridges when the difference between the two pressure gauges is greater than or equal to 20 psi (1.4 bar)